IRC 2006, Section 408.3 Unvented crawl space-
Ventilation openings in under-floor spaces specified in Sections R408.1 and R408.2 shall not be required where:
- Exposed earth is covered with a continuous vapor retarder.
- One of the following is provided:
2.1 Continuously operated mechanical exhaust ventilation at a rate equal to 1.0 cfm (0.47 L/s) for each 50 ft² (4.7 m²) of crawlspace floor area, including an air pathway to the common area, and perimeter walls insulated in accordance with Section N1102.2.8.
2.2 Conditioned air supply sized to deliver at a rate equal to 1.0 cfm (0.47 L/s) for each 50 ft² (4.7 m²) of under-floor area including a return air pathway to the common area, and perimeter walls insulated in accordance with Section N1102.2.8.
2.3 Plenum complying with Section M1601.4 if under-floor space is used as a plenum.
International Energy Conservation Code
(IECC)
IECC 2006, Section 402.2.8 Crawl space
walls-
As an alternative to insulating floors over crawl spaces, crawl
space walls shall be permitted to be insulated when the crawl space
is not vented to the outside [excerpt].